Escalib Mills en Kit

eSCAlIb MIllS KIT 14 e S C A l I b M I l l S Md S K I T : S I T e S P I R A l S TA I R ToWe R WI TH S I d e e X I T ( bolT e d Modu l e ) Gangway ... e scalib units that are not close to the floor slabs being ser- viced, can be equiped with special brackets to adapt a gangway made of other scaf- folding components. The 2 gangway brackets (right and left) are fitted to stringers on the escalib and connected by a 1.50m scaffolding ledger. 0.21 1.50m guardrail at the bottom 1.50m ledger at the top Access onto a deck. > Gangways with front exit: Access over a parapet. Gangway over a wall. 1.00 d2 d1 L d2 d1 L d2 d1 L Right Left See technical manual for the other scaffolding items. > GANGWAY bRACKeT description Code Weight left gangway bracket 013271-2 13.0 Right gangway bracket 013270-4 9.0 > SPIGoT CouPleR description Code Weight Spigot coupler 025620-6 1.5 > 1.50 M ledGeR description Code Weight 1.50 m ledger 023609-1 5.8 Bracket Offset gangway 0.15 - 0.45 m Access by the top step. > Recommended gangway position: Centered gangway 0.30 - 0.30 m Access by the middle step. d1=0.30 1.00 d1 = d2 d2=0.30 Ledger at the bottom position on the gangway brackets. d1=0.15 1.00 d2=0.45 Ledger at the top position on the gangway brackets. d1=0.38 1.00 d2=0.22 Ledger at the bottom position on the gangway brackets. > Gangway positions special cases: Offset gangway 0.38 - 0.22 m Access by the bottom step. NB: The offset gangway 0.38 - 0.22 m cannot be moved by crane. It must be assembled on site. NB: Safety harness (individual safety gear) must be worn during build.