12 E s C A L I B M I L L s M D s : s I T E s P I R A L s T A I R C A s E W I T H s I D E E X I T EsCALIB MILLs MDs Gangway ... E scalib units that are not close to the floor slabs being ser- viced, can be equiped with special brackets to adapt a gangway made of other scaf- folding components. The 2 gangway brackets (right and left) are fitted to stringers on the Escalib and connected by a 1.50m scaffolding ledger. 0.21 1.50m ledger at the bottom Bracket 1.50m ledger at the top Offset gangway 0.15 - 0.45 m Access by the top step. Access onto a deck. > Gangways with front exit: Access over a parapet. Gangway over a wall. > Recommended gangway position: Centered gangway 0.30 - 0.30 m Access by the middle step. d1=0.30 1.00 d1 = d2 d2=0.30 Ledger at the bottom position on the gangway brackets. d1=0.15 1.00 d2=0.45 Ledger at the top position on the gangway brackets. d1=0.38 1.00 d2=0.22 Ledger at the bottom position on the gangway brackets. > Gangway positions special cases: Offset gangway 0.38 - 0.22 m Access by the bottom step. 1.00 d2 d1 L NB: The offset gangway 0.38 - 0.22 m cannot be moved by crane. It must be assembled on site. NB: safety harness (individual safety gear) must be worn during build. d2 d1 L d2 d1 L Right Left see technical manual for the other scaffolding items. > GANGWAY BRACKET Description Code Weight Left gangway bracket 013271-2 13.0 Right gangway bracket 013270-4 9.0 > sPIGoT CoUPLER Description Code Weight spigot coupler 025620-6 1.5 > 1.50 M LEDGER Description Code Weight 1.50 m ledger 023609-1 5.8